% Simulink scrip for resolve to signals.
% MATLAB version: R2017a
% Author : Shibo Jiang
% Version : 0.1
% Instructions :
%------------------------------------------------------------------------------
function resolve_signals_result = resolve_signals()
paraModel = bdroot;
% Original matalb version is R2017a
% 检查Matlab版本是否为R202017a
CorrectVersion_win = '9.2.0.556344 (R2017a)'; % windows
CorrectVersion_linux = '9.2.0.538062 (R2017a)'; % linux
CurrentVersion = version;
if 1 ~= bitor(strcmp(CorrectVersion_win, CurrentVersion),...
strcmp(CorrectVersion_linux, CurrentVersion))
warning('Matlab version mismatch, this scrip should be used for Matlab R2017a');
end
% Original environment character encoding: GBK
% 脚本编码环境是否为GBK
% if ~strcmpi(get_param(0, 'CharacterEncoding'), 'GBK')
% warning('Simulink:EncodingUnMatched', 'The target character ...
% encoding (%s) is different from the original (%s).',...
% get_param(0, 'CharacterEncoding'), 'GBK');
% end
all_line = find_system(paraModel,'FindAll','on','type','line');
% Parameters define
k = 1;
enable_rs_flag = 0;
length_line = length(all_line);
% Find the line which need propagating signals
for i = 1:length_line
% Detect 'Signal name'
current_line_name = get(all_line(i),'Name');
% Detect 'Signal name must resolve to Simulink signal object' state
current_line_rs = get(all_line(i),'MustResolveToSignalObject');
% judge whether signal has name
if 1 == isempty(current_line_name)
% no name
ne_flag = 1;
else
% have name
ne_flag = 0;
end
% judge whether signal set must resolve to signal object
if 0 == current_line_rs
rs_flag = 4;
else
rs_flag = 0;
end
% Mark the line which both resolve to signal and Name are disabled
line_b_flag = bitor(rs_flag,ne_flag);
if 4 == line_b_flag
resolve_singals_line(k) = all_line(i);
k = k + 1;
enable_rs_flag = 1;
else
% Do nothing
end
end
% set 'Signal name must resolve to Simulink signal object' to on
if 1 == enable_rs_flag
length_rs_line = length(resolve_singals_line);
for i = 1:length_rs_line
try
set(resolve_singals_line(i),'MustResolveToSignalObject',1);
catch
% do nothing
end
end
% report configurate results
resolve_signals_result = 'resolve signals successful';
else
% report configurate results
resolve_signals_result = 'No signal line need resovling to signal';
end